This comprehensive guide provides essential information for owners of the Harman Advance pellet stove. It covers safety‚ operation‚ installation‚ maintenance‚ and troubleshooting. This manual is designed to ensure safe and efficient use. It contains all the necessary information for proper use of the product.
The Harman Advance pellet stove is a sophisticated heating appliance designed for safety‚ reliability‚ and efficiency. It’s engineered to provide automatic temperature control‚ adjusting fire size to meet heating needs and even extinguishing the fire when necessary. This stove utilizes a room sensor for more accurate temperature readings‚ unlike traditional wall thermostats. The automatic ignition system ensures a convenient start-up‚ while manual operation is available for emergency situations‚ such as igniter failure. The Harman Advance is designed for both residential and shop installations and has undergone rigorous testing and certification. This pellet stove represents Harman’s commitment to quality and innovative heating solutions. Its features include a microprocessor-controlled output that manages room temperature and also has minimal maintenance requirements. The Harman Advance pellet stove provides total temperature control‚ ensuring the user can achieve a stable and comfortable temperature. It features a user-friendly control system and is designed for ease of operation.
The Harman Advance pellet stove is equipped with multiple safety devices to ensure secure operation. It’s crucial to read the entire manual before installation and use‚ as improper installation can lead to property damage‚ injury‚ or even death. This stove is approved for use in the U.S. and Canada‚ and it is also suitable for installation in mobile homes. Strict adherence to installation directions is essential to prevent house fires. Always consult local building or fire officials regarding restrictions and installation inspections. Contact local authorities for permit requirements. The structural integrity of the mobile home floor‚ wall‚ and ceiling must be maintained during installation. Do not install the unit in a sleeping room. Never connect the unit to a chimney flue serving another appliance. Avoid venting into alcove locations. Ensure all venting components meet safety standards. Always use a certified installer. Proper clearances from combustible materials must be observed to prevent fire hazards. Regular inspections and maintenance are necessary to maintain safe operation. The stove should be installed following all required clearances.
The Harman Advance pellet stove features automatic ignition and temperature control‚ making it user-friendly and efficient. The automatic system adjusts the fire size to match the heating requirements of the room. It can even extinguish the fire if needed and automatically reignite when more heat is required. This ensures consistent temperature and optimal fuel consumption. The system uses a room sensor rather than a wall thermostat for more accurate temperature control. To start the automatic ignition‚ ensure the stove is plugged into a 120 VAC‚ 60 HZ electrical source and that the igniter switch is in the “AUTO” position. Make sure that no fuel or combustible materials are in the ash pan before starting. The power light should be the only light lit. The stove will automatically adjust the fire size to match the heating needs and even put the fire out if necessary. If heat is needed after the fire is out‚ the Advance will automatically re-ignite and adjust the fire size to match the heating need. The automatic system simplifies operation and provides consistent heat.
The Harman Advance pellet stove is equipped with the capability for manual operation‚ providing essential control during emergencies or igniter failures. This feature allows the operator to manually control the stove’s operation. To initiate manual operation‚ switch the igniter to the “MANUAL” position. Ensure the unit is plugged into a 120 VAC‚ 60 HZ power source‚ with the power light being the only light illuminated. Before starting‚ make certain that no fuel or combustible materials are present in the ash pan to prevent unwanted smoke. The unit can switch between “AUTO” and “MANUAL” mode during operation. In an emergency‚ understanding manual operation is crucial for maintaining heat. Manual operation can be used when the automatic system isn’t working. During manual operation‚ the stove’s functions are controlled directly by the user‚ bypassing the automatic system. The user must monitor and adjust the stove manually‚ ensuring proper fuel supply and combustion. This feature provides a backup option for consistent heating when the automatic system is not available. It is essential to understand manual operation for optimal usage.
Proper installation of the Harman Advance pellet stove is crucial for safety and optimal performance. When selecting a location‚ several factors must be considered‚ including required clearances to combustible materials‚ proximity to a safe chimney or venting system‚ and accessibility to electrical supply. Observing these clearances is essential to prevent fire hazards. The stove should be placed at least one inch from the wall‚ though two or three inches is recommended for better access to the rear panel. This appliance is approved for installation in a shop. For mobile home installations‚ outside air is required. Do not install in a room designated for sleeping. Ensure the structural integrity of the mobile home floor‚ wall‚ and ceiling. The stove should not be connected to a chimney flue serving another appliance. Always check local building and fire codes for permit requirements. The unit must be installed by a qualified professional. Ignoring these guidelines could result in a house fire. Proper venting is also essential‚ and will be discussed in a separate section.
Proper venting is critical for the safe and efficient operation of your Harman Advance pellet stove; Several venting options are available‚ each with specific requirements. The preferred method involves venting directly through the wall‚ allowing for installation close to the wall. However‚ ensure that the vent is not placed below ventilated soffits. Always run the vent above the roof to ensure proper draft. Avoid venting into alcove locations. For mobile home installations‚ outside air is essential and must be incorporated into the venting system. Using a direct vent wall passthrough will simplify the installation process. If using an existing chimney‚ ensure it is in good condition and may require a liner. In some areas‚ the vent pipe must extend to the top of the chimney. When venting through the ceiling‚ always follow the manufacturer’s recommendations. Under no circumstance should a flue damper be installed. The vent must not be installed within 3 feet of a gas meter or regulator. Maintain a minimum clearance of 6 feet to a service regulator vent outlet. Observe all local venting codes.
Regular maintenance is crucial for the optimal performance and longevity of your Harman Advance pellet stove. Always ensure the stove is cool before commencing any maintenance tasks. Begin by emptying the ash pan regularly‚ using gloves to protect against burns. Open the side doors and release the spring latches to remove the ash pan. Periodically clean the burn pot by scraping the top and sides‚ removing accumulated debris. It’s not necessary to remove all material‚ as excess will be pushed out during the next use. The flame guide and brick panel should also be removed for cleaning. Slide the brick panel upwards and remove the flame guide. The combustion intake cover‚ located behind the ash pan‚ should be removed to clean the fan blades and rear flue tube. Rotate the retainer handle counter-clockwise to remove the cover. The heat exchanger system requires cleaning by removing the brick panel‚ flame guide‚ ash pan‚ and flue baffles. Clean the baffles and heat exchanger slots. Regular inspections and cleaning will ensure efficient and safe operation of your stove.
Encountering issues with your Harman Advance pellet stove can be frustrating‚ but many problems can be resolved with simple troubleshooting. If the stove fails to ignite‚ first check that it is properly plugged into a 120 VAC‚ 60 Hz power source‚ and ensure the igniter switch is in the correct position (AUTO for automatic or MANUAL for manual start). Verify that there is no fuel or combustibles in the ash pan. If the stove isn’t heating properly‚ ensure the room sensor is correctly installed and not obstructed. A low draft may cause issues; perform a draft test and adjust the combustion motor speed control if needed. If you notice unusual smoke‚ inspect the venting system for blockages and make sure all connections are secure. Check for proper fuel feed and that the burn pot is not overly full of ash. If error lights appear‚ consult the manual for specific error code explanations. If you are unable to resolve the problem‚ contact a certified Harman dealer for assistance.
The Harman Advance pellet stove utilizes an advanced control system‚ featuring a room sensor rather than a traditional wall thermostat for more precise temperature regulation. The control panel allows users to switch between automatic and manual operation. In automatic mode‚ the stove adjusts its fire size to match heating needs‚ and can even extinguish and re-ignite itself as necessary. The user interface may include a knob for varying the distribution blower speed‚ typically marked from 1 to 7. Some models may offer a “Stove Temp Mode” which allows adjusting the stove temperature using a special DDM monitor. It is essential to understand the various modes and settings to optimize the stove’s performance and efficiency. A 7-day programmable thermostat may be used‚ allowing for scheduled occupied and unoccupied periods‚ typically maintaining a consistent room temperature through low burn mode. The igniter can also be set to manual for low burn when the stove cools down. Always refer to your specific model’s manual for detailed instructions and feature availability.